Ultrafiltration

Ultrafiltration is a separation process using membranes with pore sizes in the range of 0.1 to 0.001 micron. Typically, ultrafiltration will remove high molecular-weight substances, colloidal materials, and organic and inorganic polymeric molecules. Low molecular-weight organics and ions such as sodium, calcium, magnesium chloride, and sulfate are not removed. 

Because only high-molecular weight species are removed, the osmotic pressure differential across the membrane surface is negligible.  Low applied pressures are therefore sufficient to achieve high flux rates from an ultrafiltration membrane. Flux of a membrane is defined as the amount of permeate produced per unit area of membrane surface per unit time. Generally flux is expressed as gallons per square foot per day (GFD) or as cubic meters per square meters per day.

 
Ultrafiltration membranes can have extremely high fluxes but in most practical applications the flux varies between 50 and 200 GFD at an operating pressure of about 50 psig in contrast, reverse osmosis membranes only produce between 10 to 30 GFD at 200 to 400 psig.
 
Ultrafiltration Membranes
 
Ultrafiltration Membrane modules come in plate-and-frame, spiral-wound, and tubular configurations. All configurations have been used successfully in different process applications. Each configuration is specially suited for some specific applications and there are many applications where more than one configuration is appropriate. For high purity water, spiral-wound and capillary configurations are generally used.  The configuration selected depends on the type and concentration of colloidal material or emulsion. For more concentrated solutions, more open configurations like plate-and- frame and tubular are used. 
 
In all configurations the optimum system design must take into consideration the flow velocity, pressure drop, power consumption, membrane fouling and module cost.
 
Membrane Materials
 
A variety of materials have been used for commercial ultrafiltration membranes, but polysulfone and cellulose acetate are the most common. Recently thin-film composite ultrafiltration membranes have been marketed. For high purity water applications the membrane module materials must be compatible with chemicals such as hydrogen peroxide used in sanitizing the membranes on a periodic basis.

Molecular-Weight Cutoff 
 
Pore sizes for ultrafiltration membranes range between 0.001 and 0.1 micron.  However, it is more customary to categorize membranes by molecular-weight cutoff. For instance, a membrane that removes dissolved solids with molecular weights of 10,000 and higher has a molecular weight cutoff of 10,000. Obviously, different membranes even with the same molecular-weight cutoff, will have different pore size distribution.  In other words, different membranes may remove species of different molecular weights to different degrees. Nevertheless, molecular-weight cutoff serves as a useful guide when selecting a membrane for a particular application.
 
Factors Affecting the Performance of Ultrafiltration
 
There are several factors that can affect the performance of an   ultrafiltration system. A brief discussion of these is given here.
 
Flow Across the Membrane Surface. 
 
The permeate rate increases with the flow velocity of the liquid across the membrane surface.   Flow velocity if especially critical for liquids containing emulsions or suspensions.  Higher flow also means higher energy consumption and larger pumps.  Increasing the flow velocity also reduces the fouling of the membrane surface. Generally, an optimum flow velocity is arrived at by a compromise between the pump horsepower and increase in permeate rate.
 
Operating Pressure.
 
Permeate rate is directly proportional to the applied pressure across the membrane surface. However, due to increased fouling and compaction, the operating pressures rarely exceed 100 psig and are generally around 50 psig. In some of the capillary-type ultrafiltration membrane modules the operating pressures are even lower due to the physical strength limitation imposed by the membrane module.
 
Operating Temperature.
 
Permeate rates increase with increasing temperature. However, temperature generally is not a controlled variable.It is important to know the effect of temperature on membrane flux in order to distinguish between a drop in permeate due to a drop in temperature and the effect of other parameters.
 
Performance of Ultrafiltration Systems
 
In high purity water systems, ultrafiltration is slowly replacing the traditional 0.2-micron cartridge filters. In Japan, practically all of the semiconductor industry follows this practice.  An ultrafiltration membrane with a molecular-weight cutoff of 10,000 has a nominal pore size of 0.003 micron.  When an ultrafiltration membrane is used instead of a 0.2-micron cartridge filter, particle removal efficiency is greatly improved.  In addition, ultrafiltration membranes are not susceptible to the problem of bacteria growing through them, as is the case with 0.2-micron filters.
 
In a recent study (1), the performance of an ultrafilter was compared with that of a 0.2-micron cartridge filter. Some of these results are given in Table A.
 
The Ultrafilter used in the study had a molecular-weight cutoff of 100,000- (pore size 0.006 micron). As the requirements for the quality of high purity water become more stringent, we can expect to see an increasing use of ultrafiltration as a final filter.
 
Operation and Maintenance
 
Ultrafiltration system operation and maintenance is similar to that of reverse osmosis systems. Daily records of feed and permeate flow, feed pressure and temperature, and pressure drop across the system should be kept.  Membranes should be cleaned when the system  permeate rate drops by 10% or more.  Feed flow is critical to the operation of ultrafiltration systems. A drop in feed flow may be due to a problem in the prefilter (if any), with the flow control valve, or with the pump itself.  When the system is shut down for more than two days, a bacteriocide should be circulated through the membranes. At restart, permeate should be diverted to drain until all the bacteriocide is removed.
 