A variety of materials have been used for commercial ultrafiltration membranes, but polysulfone and cellulose acetate are the most common. Recently thin-film composite ultrafiltration membranes have been marketed. For high purity water applications the membrane module materials must be compatible with chemicals such as hydrogen peroxide used in sanitizing the membranes on a periodic basis.
Pore sizes for ultrafiltration membranes range between 0.001 and 0.1 micron. However, it is more customary to categorize membranes by molecular-weight cutoff. For instance, a membrane that removes dissolved solids with molecular weights of 10,000 and higher has a molecular weight cutoff of 10,000. Obviously, different membranes even with the same molecular-weight cutoff, will have different pore size distribution. In other words, different membranes may remove species of different molecular weights to different degrees. Nevertheless, molecular-weight cutoff serves as a useful guide when selecting a membrane for a particular application.
Factors Affecting the Performance of Ultrafiltration
There are several factors that can affect the performance of an ultrafiltration system. A brief discussion of these is given here.
Flow Across the Membrane Surface.
The permeate rate increases with the flow velocity of the liquid across the membrane surface. Flow velocity if especially critical for liquids containing emulsions or suspensions. Higher flow also means higher energy consumption and larger pumps. Increasing the flow velocity also reduces the fouling of the membrane surface. Generally, an optimum flow velocity is arrived at by a compromise between the pump horsepower and increase in permeate rate.
Operating Pressure.
Permeate rate is directly proportional to the applied pressure across the membrane surface. However, due to increased fouling and compaction, the operating pressures rarely exceed 100 psig and are generally around 50 psig. In some of the capillary-type ultrafiltration membrane modules the operating pressures are even lower due to the physical strength limitation imposed by the membrane module.
Operating Temperature.
Permeate rates increase with increasing temperature. However, temperature generally is not a controlled variable.It is important to know the effect of temperature on membrane flux in order to distinguish between a drop in permeate due to a drop in temperature and the effect of other parameters.
Performance of Ultrafiltration Systems
In high purity water systems, ultrafiltration is slowly replacing the traditional 0.2-micron cartridge filters. In Japan, practically all of the semiconductor industry follows this practice. An ultrafiltration membrane with a molecular-weight cutoff of 10,000 has a nominal pore size of 0.003 micron. When an ultrafiltration membrane is used instead of a 0.2-micron cartridge filter, particle removal efficiency is greatly improved. In addition, ultrafiltration membranes are not susceptible to the problem of bacteria growing through them, as is the case with 0.2-micron filters.
In a recent study (1), the performance of an ultrafilter was compared with that of a 0.2-micron cartridge filter. Some of these results are given in Table A.
The Ultrafilter used in the study had a molecular-weight cutoff of 100,000- (pore size 0.006 micron). As the requirements for the quality of high purity water become more stringent, we can expect to see an increasing use of ultrafiltration as a final filter.
Operation and Maintenance
Ultrafiltration system operation and maintenance is similar to that of reverse osmosis systems. Daily records of feed and permeate flow, feed pressure and temperature, and pressure drop across the system should be kept. Membranes should be cleaned when the system permeate rate drops by 10% or more. Feed flow is critical to the operation of ultrafiltration systems. A drop in feed flow may be due to a problem in the prefilter (if any), with the flow control valve, or with the pump itself. When the system is shut down for more than two days, a bacteriocide should be circulated through the membranes. At restart, permeate should be diverted to drain until all the bacteriocide is removed.